Detecting levels amino acids for proteins of different for patients with myeloma and comparing them using a portable Raman spectrometer

Abstract

Raman spectroscopy gives a simple, non-extended approach to determining the malignant growth of both research and clinical cases. In the present study considered the detection of inconsistencies between the spectral features of blood in myeloma, to the distinction throughout fat and protein. In this study, we try to reveal contradictions and changes in the relative forces of myeloma by spectroscopic features. In this study compares data analysis, received from A polynomial approximation PolyFit method and ModPoly method and finally I-ModPoly method, and compares the results of each, a method with the multivariate curve resolve - alternate least squares (MCR - ALS) regression strategy of analyze spectral data of information with a different concentration. Raman groups (1154 cm-1, 1255-1265 cm-1, 1337cm-1, 1451-1465 cm-1, 1524cm-1, 1660-1670 cm-1) relate to amino acids for proteins. Spectroscopic highlights were utilized to quantify the all-out protein convergence of blood plasma in myeloma. The MCR regression strategy was utilized to analyze information spectral data at different concentrations. It was observed that was a remarkable variance in the consistency of the reduction between the two spectrum. So that, the qualitative of spectral data promoted the abnormality proliferation of the monoclonal (IgA) plasma proteins over the plasma. Thereby signalize the existence of myeloma in the blood. A result of Increased amino acids in connection with comparing touchy cellular lines.

References

  • Atkins CG, Buckley K, Blades MW, Turner RF (2017) Raman spectroscopy of blood and blood components. Applied spectroscopy, 71(5):767-793.
  • Cadusch PJ, Hlaing MM, Wade SA, McArthur SL, Stoddart PR (2013) Improved methods for fluorescence background subtraction from Raman spectra. Journal of Raman Spectroscopy, 44(11):1587-1595.
  • Costa DB, Shin B, Cooper DL (2004) Pneumococcemia as the presenting feature of multiple myeloma Am. J. Hematol. 77:277-81.
  • De Gelder J, De Gussem K, Vandenabeele P, Moens L (2007) Reference database of Raman spectra of biological molecules. Journal of Raman Spectroscopy: An International Journal for Original Work in all Aspects of Raman Spectroscopy, Including Higher Order Processes, and also Brillouin and Rayleigh Scattering, 38(9):1133-1147.
  • De Veij M, Vandenabeele P, De Beer T, Remon JP, Moens L (2009) Reference database of Raman spectra of pharmaceutical excipients. Journal of Raman Spectroscopy: An International Journal for Original Work in all Aspects of Raman Spectroscopy, Including Higher Order Processes, and also Brillouin and Rayleigh Scattering, 40(3):297-307.
  • Ellis DI, Cowcher DP, Ashton L, O’Hagan S, Goodacre R (2013). Illuminating disease and enlightening biomedicine: Raman spectroscopy as a diagnostic tool. Analyst, 138(14):3871-3884.
  • Eslick R, Talaulikar D (2013) Multiple myeloma: from diagnosis to treatment. Australian family physician, 42(10):684.
  • Feng X, Moy AJ, Nguyen HT, Zhang J, Fox MC, et al. (2017). Raman active components of skin cancer. Biomedical optics express, 8(6):2835-2850.
  • Franco D, Trusso S, Fazio E, Allegra A, Musolino C, et al. (2017). Raman spectroscopy differentiates between sensitive and resistant multiple myeloma cell lines. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 187:15-22.
  • Genty V, El-Khoury V, Liautaud-Roger F, Dine G, Dufer J (2005) Nuclear chromatin patterns in 3 glucocorticoid-resistant RPMI 8226 human myeloma cell sub-lines: correlations with cell growth and immunological phenotype. Cancer biology & therapy, 4(8):832-839.
  • Jie C, Meizhen H, Ye Zou, Biao S (2016) Multiple myeloma detection based on blood plasma surface-enhanced Raman spectroscopy using a portable Raman spectrometer, Laser Physics Letters, 13(10).
  • Kang JW, Singh SP, Nguyen FT, Lue N, Sung Y, So PT, Dasari RR (2016) Investigating effects of proteasome inhibitor on multiple myeloma cells using confocal Raman microscopy. Sensors, 16(12):2133.
  • Kumar K, Mishra AK (2012) Application of ‘multivariate curve resolution alternating least square (MCR–ALS)’analysis to extract pure component synchronous fluorescence spectra at various wavelength offsets from total synchronous fluorescence spectroscopy (TSFS) data set of dilute aqueous solutions of fluorophores. Chemometrics and Intelligent Laboratory Systems, 116:78-86.
  • Mills JR, Barnidge DR, Dispenzieri A, Murray DL (2017) High sensitivity blood-based M-protein detection in sCR patients with multiple myeloma. Blood cancer journal, 7(8):e590-e590.
  • Mohamed A, Collins J, Jiang H, Molendijk J, Stoll T, Torta F (2020) Concurrent lipidomics and proteomics on malignant plasma cells from multiple myeloma patients: Probing the lipid metabolome. PLoS ONE 15(1):e0227455. https://doi.org/10.1371/journal.pone.0227455
  • Movasaghi Z, Rehman S, Rehman IU (2007) Raman spectroscopy of biological tissues. Applied Spectroscopy Reviews, 42(5):493-541.
  • Pence I, Mahadevan-Jansen A (2016) Clinical instrumentation and applications of Raman spectroscopy. Chemical Society Reviews, 45(7):1958-1979.
  • Poudel B, Mittal A, Shrestha R, Farooqui MS, Yadav NK, Shukla PS (2012) Liver involvement in multiple myeloma: a hospital based retrospective study. Asian Pacific Journal of Cancer Prevention, 13(5):2153-2155.
  • Sankari G, Aishwarya TS, Gunasekaran S, Surapaneni KM (2011) Analysis of multiple myeloma by FTIR spectroscopy coupled with statistical analysis. Journal of Clinical and Diagnostic research, 5:1001-1007.
  • Tamiru S, Tesfaye K, Mamo G (2015) Analysis of Rainfall and Temperature Variability to Guide Sorghum (Sorghum Bicolar) Production in Miesso Areas, Eastern Ethiopia. International Journal of Sustainable Agricultural Research, 2(1):1-11.
  • Zhang D, Wang P, Slipchenko MN, Ben-Amotz D, Weiner AM, Cheng JX (2013) Quantitative vibrational imaging by hyperspectral stimulated Raman scattering microscopy and multivariate curve resolution analysis. Analytical chemistry, 85(1):98-106.
  • Zhang X, Tauler R (2013) Application of multivariate curve resolution alternating least squares (MCR-ALS) to remote sensing hyperspectral imaging. Analytica chimica acta, 762:25-38.
  • Zhao J, Lui H, McLean DI, Zeng H (2007) Automated autofluorescence background subtraction algorithm for biomedical Raman spectroscopy. Applied spectroscopy, 61(11):1225-1232.
  • Zub KA, Sousa MMLd, Sarno A, Sharma A,Demirovic A, Rao S, (2015) Modulation of Cell Metabolic Pathways and Oxidative Stress Signaling Contribute to Acquired Melphalan Resistance in Multiple Myeloma Cells. PLoS ONE 10(3):e0119857. https://doi.org/10.1371/journal.pone.011985

License

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.